Blind range St
- Reliable object recognition is not possible within the blind range (St). Objects within this blind range may cause false switching of the sensor.
Scanning range far limit Sde
- The scanning range far limit Sde can be continuously adjusted either by the built-in pot or by teaching in.
Scanning range close limit Sdc
- The scanning range close limit Sdc can be electronically set using the sensor's Teach-in features.
Scanning range Sd
- Objects within the scanning range Sd are detected up to the set scanning range far limit Sde
|
| product family |
sample picture |
housing |
sensing range sd |
response time |
sync. |
features |
  |
|
  |
  |
  |
  |
|
UNAM 12 (Sde = 200 mm)
Ultrasonic proximity sensors
|
 |
12x70 mm, metal
|
10 ... 200 mm
|
< 10 ms
|
-
|
Teach-in input, IP 67
|
UNAM 12 (Sde = 400 mm)
Ultrasonic proximity sensors
|
 |
12x70 mm, metal
|
40 ... 400 mm
|
< 25 ms
|
-
|
Teach-in input, IP 67
|
UNAM 12 (with beam columnator)
Ultrasonic proximity sensors
|
 |
12x100 mm, metal
|
5 ... 70 mm
|
< 10 ms
|
-
|
IP 67
|
UNAM 18 (face chemically resistant)
Ultrasonic proximity sensors
|
 |
18x91,5 mm, metal
|
100 ... 1000 mm
|
< 50 ms
|
-
|
Internal and external Teach-in, chemically resistant, IP 67
|
UNAM 18 (with Teach-in)
Ultrasonic proximity sensors
|
 |
18x90 mm, metal
|
100 ... 1000 mm
|
< 50 ms
|
-
|
IP 67
|
UNAM 18 (without Teach-in)
Ultrasonic proximity sensors
|
 |
18x89 mm, metal
|
100 ... 700 mm
|
< 50 ms
|
yes
|
IP 67
|
UNAM 30
Ultrasonic proximity sensors
|
 |
30x70 mm, metal
|
200 ... 1500 mm
|
< 100 ms
|
-
|
IP 67
|
UNAM 50
Ultrasonic proximity sensors
|
 |
30x95 mm, metal
|
350 ... 2500 mm
|
< 160 ms
|
yes
|
IP 67
|
UNAR 18 (Sde = 1000 mm)
Ultrasonic proximity sensors
|
 |
18x91,5 mm, metal
|
100 ... 1000 mm
|
< 50 ms
|
-
|
Internal and external Teach-in, chemically resistant, IP 67
|
UNAR 18 (Sde = 400 mm)
Ultrasonic proximity sensors
|
 |
18x91,5 mm, metal
|
60 ... 400 mm
|
< 25 ms
|
-
|
Internal and external Teach-in, chemically resistant, IP 67
|
|